The Normal Choroidal Thickness In Southern Thailand
Author: Jirarattanasopa P, Panon N, Hiranyachattada S, Bhurayanontachai P
Publisher: Derivative Works
5 pages
One time payment: €0.00
Required subscription: Free
Type of publication: Article
ISBN/ISSN: 1177-5483
DOI: 10.2147/71343
Follow this publisher

Share this publication:

Description:

Objective: To investigate the association between subfoveal choroidal thickness in healthy southern Thailand volunteers and age, axial length, and refractive error. Subjects and methods: This was a prospective cross-sectional case series. A total of 210 eyes of 105 healthy volunteers (86 women, age 23–83 years) in southern Thailand were examined with enhanced depth-imaging optical coherence tomography. Subjects with systemic diseases that may affect the choroidal vascular blood vessels, such as diabetes, impaired renal function, and hypertension, were excluded. Refractive error and axial length were measured by autorefractometry and an IOLMaster, respectively. Subfoveal choroidal thickness was measured from the outer border of the retinal pigment epithelium to the inner scleral border in the subfoveal area. Results: The mean subfoveal choroidal thickness was 279.4±75.49 µm, and the mean age was 46.4±16.45 years. Subfoveal choroidal thickness was negatively correlated with age (r2 =0.33, P,0.0001) and axial length (r2 =0.02, P,0.02). Multivariable regression analysis showed subfoveal choroidal thickness was positively and negatively correlated with a spherical equivalent refractive error and axial length, respectively, when adjusted for age. Conclusion: Age is the most important factor in choroidal thickness rather than axial length and refractive error. Subfoval choroidal thickness was decreased 2.67 µm every year and 14.59 µm with 1 mm increase in axial length. 

About the publisher:

We are a publishing house devoted to reuse CC-BY licensed published materials.

 

Using CC-BY licenses:

YOU ARE FREE TO:

  • Adapt — remix, transform, and build upon the material
  • for any purpose, even commercially.
  • The licensor cannot revoke these freedoms as long as you follow the license terms.

UNDER THE FOLLOWING TERMS:

  • No additional restrictions — You may not apply legal terms or technological measures that legally restrict others
    from doing anything the license permits.

NOTICES:

  • You do not have to comply with the license for elements of the material in the public domain or where your use is permitted by an applicable exception or limitation.
  • No warranties are given. The license may not give you all of the permissions necessary for your intended use. For example, other rights such as publicity, privacy, or moral rights may limit how you use the material.

Select a payment method